Characteristics of an eddy current testing system

· the sensor socket is designed modular and is easy to install and therefore all-purpose applicable in crawler systems
· automatic retracting movements of the (test-) tools at power failure
· ovalities of the tube inside surface may be covered by an automatic tracking system
· defects from a depth of 1 mm can be detected regardless of its orientation
· very good signal separation of surface effects (noise) and defect signals
· test coverage = 100% of the tube inside surface
· exact positioning and repeatability by precise encoder
· additional integration of a video system at the crawler
· adjustable lighting for camera orientation/ visual inspection